How much compressed air does the medical industry need?
The demand for compressed air in the medical industry varies depending on the type of equipment and needs to be taken into accountDevice functions, patient safety and hygiene standards。The following are specific requirements and analysis of typical application scenarios:
1. Core pressure needs
application scenarios | pressure range | flow demand(Example) | crucial requirement |
---|---|---|---|
ventilator | 0.4-0.6 MPa | 50-200 L/min | Stable pressure to prevent tidal volume fluctuations from affecting patient breathing |
Operating table/examination table | 0.6-0.8 MPa | 300-800 L/min | Quick response to position adjustment, need to be equipped with air storage tank |
dental unit | 0.5-0.7 MPa | 100-300 L/min | An integrated drying system is required to prevent water mist from entering the mouth |
Laboratory automation equipment | 0.4-0.8 MPa | 10-100 L/min | High-precision filter (0.01 μm) is required |
negative pressure isolation ward | -0.02 MPa | variable control | Requires a dedicated negative pressure fan, non-traditional air compressor application scenarios |
2. Special quality requirements
- aseptic processing:
- Surgery-related equipment needs to be configuredHigh temperature sterilization filter(Resistance to 121℃ steam).
- End air needs to pass throughHEPA filter(0.3 μm efficiency ≥99.97%).
- Low dew point control:
- Respiratory gas contact equipment needs to meet-40℃ pressure dew point(ISO 8573-1 Class 1)。
- recommendedAdsorption dryer + membrane dryerCombination.
- oil-free guarantee:
- must useoil-free compressor(Such as dry screw machines).
- terminal installationcoalescence oil mist filter(Residue ≤0.003 ppm).
3. Typical system configuration
- Respiratory support equipment:
- Compressor + air storage tank (≥1 m³)+ freeze dryer + activated carbon filter + bacterial filter.
- Operating room integrated system:
- Central gas supply station (equipped with multiple oilless screw machines)+ annular pipe network + zoning pressure regulating valve.
- laboratory robot:
- Silent oil-free air compressor (≤60 dB)+ micro drying module + stainless steel pipe.
4. Compliance requirements
- standards meet: Need to meet ISO 7396-1 (Medical Gas Systems), ISO 8573-1 and other specifications.
- certification requirements: Compressors need to pass MDSAP (Medical Device Single Audit Procedure) certification.
- monitoring requirements: InstallationOnline dew point meterandOil content detector, data retention ≥2 years.
5. Selection suggestions
- compressor type:
- preferenceFrequency conversion oilless screw machine(Energy saving and stable pressure).
- Recommended for standby unitspiston compressor(Responding to sudden high demand).
- material requirements:
- Parts that come into contact with medical gases requireElectropolished stainless steel(Ra≤0.4 μm)。
- seal utilizesplatinum-cured siliconeorPTFE。
- intelligent monitoring:
- configuredremote monitoring system, push air quality alarms in real time.
- advice integrationPreventive maintenance module, predict the filter element replacement cycle.
summary: The compressed air system in the medical industry needs to focus on “safety, cleanliness and stability”. It is recommended to be designed by a professional medical engineering team and regularly undergo third-party verification (such as testing according to HTMS standards). For life support equipment (such as ECMO), an independent backup air source and a manual switching device are required.