Industry general simple algorithm: actual gas production ≈ rated power of air compressor ÷ 6, 1kW power corresponds to 0.16~0.17 m/min gas production, for example, 15kw air compressor estimated gas production is about 2.5 m/min, which is only…
A simple judgment standard: if the daily unloading time of the existing power frequency air compressor exceeds 15% of the total operating time, obvious power saving benefits can be obtained by replacing the frequency conversion model.
Under daily working conditions, the air storage tank shall be drained no less than 4 times per shift. In wet weather, the frequency shall be flexibly increased according to the actual drainage volume, and automatic drainage device can…
The gas for instrument shall be set up independently with the pipe network of compressed air of common power process, and the pretreatment of deoiling, drying and dust removal shall be done well to avoid cross-contamination of gas…
There is a clear difference between the flow and displacement of the air compressor. The core definition of the two is completely different from the actual direction. The specific differences are as follows: 1. Core Definition Differences Displacement:…
Will the air compressor explode if it is not drained for a long time? Explain the complete risk logic of explosion caused by water accumulation in the air compressor in detail, with a scene-by-scene drainage operation frequency meter…
the setting of gas source pressure in chemical plants needs to be combined with specific process requirements and equipment characteristics, and there are usually the following rules: 1. basic pressure range the gas source pressure of most chemical…
Permanent magnet air compressor achieves energy efficiency optimization through permanent magnet motor technology, and its power saving characteristics are mainly due to the improvement of motor design principle and operation mode. following starting from the technical characteristics and…
Latest comments